Add to Cart
magnetic heat counter, electromagnetic water flow meter Temperature: 95 °C DN80
Description
The magnetic flow meter does not obstruct flow, so it can be applied to clean, sanitary, dirty, corrosive and abrasive liquids. Magnetic flowmeters can be applied to the flow of liquids that are conductive, so hydrocarbons and gases cannot be measured with this technology due to their non-conductive nature and gaseous state, respectively.
Electromagnetic flowmeters do not require much upstream and downstream straight run so they can be installed in relatively short meter runs. Magnetic flowmeters typically require 3-5 diameters of upstream straight run and 0-3 diameters of downstream straight run measured from the plane of the magnetic flowmeter electrodes.
Features
Technical data
Product name | Electromagnetic flowmeter | ||
Product type | Local|compact display | Remote display | Signal converter |
Model | IYF-E | IYF-F | IRT |
Pipe Diameter (mm) | DN10-DN2000 | ||
Power supply | 100-240 VAC / 18-36 VDC | ||
Accuracy | + 0.5% | + 0.5% | + 0.5% |
Power consumption | <6w | <6w | <6w |
Enclosure rating | IP65 | IP68 | IP65 |
Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ |
Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ |
Relative humidity | 10-90% | 10-90% | 10-90% |
Meter ratio | 1:100 | 1:100 | 1:100 |
Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow |
Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet |
Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency |
Accuracy
Pipe Dia (mm) | Velocity (m/s) | Accuracy |
3-20 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout | |
25-600 | 0.1-0.3 | + 0.25% FS |
0.3-1 | + 0.5% Readout | |
1-15 | + 0.3% Readout | |
700-3000 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout |
Model selection
Notice on the selection of local type and remote type:
Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
remote type in the following conditions:
No | Model | ||||||||
YF | Electromagnetic flowmeter | ||||||||
TF | Turbine | ||||||||
VF | Votex | ||||||||
LX | Vane wheel | ||||||||
T | Ultrasonic | ||||||||
E/F display mode | E: compact/local display, F: remote display | ||||||||
Pipe Dia | Type (mm) | ||||||||
xxxx | 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 | ||||||||
Code | Accuracy | ||||||||
1 | + 0.5% FS | ||||||||
2 | + 1.0% FS | ||||||||
3 | + 0.2% FS | ||||||||
Code | Type | ||||||||
N | Converter: 12 / 24 VDC, pulse output | ||||||||
A | Transmitter: 24VDC, 4-20mA outpt | ||||||||
B | Intelligent, Lion battery, no local display | ||||||||
G | Smart, local display, 4-20mA output | ||||||||
C1 | Smart, local display, RS485 | ||||||||
C2 | Smart, local display, HART | ||||||||
Code | Type | ||||||||
S | Carbon steel housing | ||||||||
L | Stainless steel housing | ||||||||
G | High pressure housing | ||||||||
HL | 316L electrode | ||||||||
HTi | Titanium electrode | ||||||||
HTa | Tantlum electrode | ||||||||
HC | Hastelloy-C electrode | ||||||||
L1 | Liquid media | ||||||||
L2 | Gas media | ||||||||
P | Pressure compensation | ||||||||
T | Temperature compensation | ||||||||
PT | Pressure&Temp. Compensation | ||||||||
F | PTFE liner | ||||||||
X | Rubber liner | ||||||||
Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner |
Applicable metering liquid:
Non-applicable metering medial
Pipe Diameter, flow volume and product dimension
Dia | Flow volume (m3/h) | Product dimension (mm) | |||||
(mm) | Normal | Min | Max | L | D | H | H1 |
15 | 1.5 | 0.06 | 9.5 | 150 | 95 | 272 | 254 |
20 | 2.5 | 0.11 | 16.9 | 105 | 277 | 254 | |
25 | 3.5 | 0.18 | 26.5 | 115 | 283 | 254 | |
32 | 6 | 0.29 | 43.6 | 140 | 297 | 270 | |
40 | 10 | 0.45 | 67.8 | 150 | 307 | 280 | |
50 | 15 | 0.71 | 106.0 | 200 | 165 | 318 | 294 |
65 | 25 | 1.19 | 179.1 | 185 | 337 | 313 | |
80 | 40 | 1.81 | 271.4 | 200 | 352 | 326 | |
100 | 60 | 2.83 | 424.1 | 250 | 220 | 371 | 344 |
125 | 100 | 4.42 | 665 | 250 | 401 | 372 | |
150 | 135 | 6.36 | 954 | 300 | 285 | 431 | 403 |
200 | 250 | 11.3 | 1696 | 350 | 340 | 486 | 460 |
250 | 375 | 17.66 | 2650 | 400 | 395 | 547 | 511 |
300 | 540 | 25.43 | 3817 | 450 | 445 | 597 | 565 |
350 | 735 | 34.62 | 5195 | 505 | 657 | 620 | |
400 | 960 | 45.22 | 6785 | 500 | 565 | 717 | 675 |
450 | 1200 | 57.23 | 8588 | 550 | 615 | 757 | 727 |
500 | 1500 | 70 | 10602 | 600 | 670 | 817 | 782 |
600 | 2160 | 100 | 15268 | 780 | 917 | 782 | |
700 | 2950 | 138 | 20781 | 700 | 895 | 1027 | 1068 |
800 | 3850 | 180 | 27100 | 800 | 1015 | 1137 | 1157 |
Industrial applications
Chemical | Food & beverage | Paper mill |
Metallurgy | Environment protection | Hydraulic |
Mining | Stainless | Petroleum |
Pharmacy | Air conditioner | Effluent treatment plant |
Seawater desalination | Pharmacy | Water treatment |
Competitive advantage
Details demonstration
Inhouse PCB production Silicon steel transformer Calibration line
How to use the magnetic flow meter
The ElectroMagnetic flowmeters measure the velocity of conductive liquids in pipes, such as water, acids, caustic, and slurries. Magnetic flowmeters can measure properly when the electrical conductivity of the liquid is greater than approximately 5μS/cm. Be careful because using magnetic flowmeters on fluids with low conductivity, such as deionized water, boiler feed water, or hydrocarbons, can cause the flowmeter to turn off and measure zero flow.